Showing results: 841 - 855 of 1156 items found.
-
CP160B -
Teledyne ICM
Next to the CP120B, the CP160B is the slightly more powerful version of our ultra-light, compact and battery operated constant potential portable X-Ray generators. Allowing penetration reaching up to 30 mm for steel, the CP160B is the perfect tool for specific NDT applications that require repetitive short exposures, as well as security applications.
-
L12531 -
Hamamatsu Photonics K.K.
Sealed type microfocus x-ray source using the transmission target. Tube voltage : 40 to 110 kV, Maximum output : 16 W, Minimum resolution : 2 um, Short FOD : 1 mm, X-ray beam angle : 120 degree, Communication method : RS-232C.
-
Expanded Beam Size 5 and 12 Contacts -
Smiths Interconnect
Expanded Beam Fiber Optic Contact technology is specifically designed to fit into standard size 12 cavities of MIL-DTL-38999 Series I, III and IV connectors. The size 12 contact provides a robust fiber optic interconnection with low susceptibility to contamination and fits a variety of cable types with diameters from 1.6 to 2.2 mm with additional versions available upon request. The contacts are rear release/rear removable with standard size 12 removal tool.
-
PM-65 -
Panasonic Industrial Devices Sales Company of America
The Panasonic PM-65 Sensor has a beam emitting / receiving distance of 6 mm. The beam emitting and receiving areas are 0.5 mm thinner compared to conventional models even though the external dimensions have not changed. As a result, the distance between the beam-emitting and the beam-receiving points have increased by 1 mm thereby reducing the possibility of sensing objects colliding.
-
PDMS-102 -
FiveLab Co.,Ltd.
Rotating Retarder MethodLight Source : Laser Diode (max. 4 wavelength; ex.650,690,780,830nm)Beam Diameter : approximately Φ2 - 2.5 (mm)
-
HORIBA, Ltd.
We offer a range of OEM instruments from miniature fiber spectrometers to research-grade grating spectrometer systems with TE or LN2-cooled CCD and InGaAs detectors.HORIBA Scientific provides miniature CCD and PDA USB spectrometers as well as 70 to 1250 mm focal length imaging spectrometers with single and multichannel detectors.If you are not a future OEM and are looking for larger, research-grade spectroscopy systems (focal lengths of 1/4 meter spectrometers and longer), please visit our Custom Spectroscopy Division
-
Applied Image, Inc.
There are two SINE Sinusoidal arrays designed for FBI applications: the SINE M-13-60-S-RM and the SINE M-13-60-FBI Kit.The SINE M-13-60-S-RM was designed jointly by the Federal Bureau of Investigation, of Washington DC, and MITRE, of Bedford MA. The primary function of this Target is for computing Modulation Transfer Function (MTF) evaluation in live scanner fingerprint systems for conformance to Integrated Automated Fingerprint Identification Systems (AFIS) image quality requirements. The array is on reflective material measuring 16mm x 16mm with sinusoidal arrays ranging in frequency from 1.0 to 10.0 cycles per mm; with nominal modulation of the sinusoidal areas at 60%. The top and bottom rows are density scales, from 0.20 to 1.20 densities.The SINE M-13-60-FBI Kit consist of two individual components, the SINE M-13-60-1X-RM and the RR1-N-RM Ronchi Ruling grating.
-
Axiomtek Co., Ltd.
ATX MotherboardAxiomtek's high performance industrial ATX motherboards (305 x 244 mm) support a wide range of computing capacities, rich I/Os and expansion slots. The ATX motherboards are ideal platforms for applications in digital video recorder, POS system, intelligent transportation system, multi-media center and more.
-
Vitech A1905 -
ViTec Co. Ltd
Modules A1905 are designed for pulsed or continuous illumination of objects in machine vision systems. The time of ignition (90%) and blanking (10%) of the module is less than 1 μs with jitter of the front(jitter) no more than 2 μs, which allows the modules to be used for exposure with "slow" cameras.The control input is compatible with npn, pnp, "open collector", TTL, LVTTL, RS422 (Basler racer) outputs.Modules can be made with light-emitting diodes of the following colors:Infrared - wavelength 730 or 850 nm;Red - wavelength 620-630 nm;Green - wavelength 520-530 nm;Blue - wavelength 460-470 nm;Ultraviolet - wavelength 365 or 400 nm;White - with a color temperature of 5000K.
-
-
72-6638 -
Tenma
An instrument to accurately measure air velocity and wind speed in air conditioning and heating systems as well as for environmental monitoring.
-
FI-18 Series -
InScan Limited (SIP) Co., Ltd.
InScan FI-18 is a compact and high performance fully automatic double sided AVI system for Final Inspection of PCB boards.The setup is based on golden board and CAD data which greatly simplifies the setup process. The FI-18 series inspects and processes a double sided board sized 210X300 mm 5.5 sec. Superior interline high resolution CCD sensor.
-
ZET 7152-N-VER.1 -
ZETLAB Company
Digital accelerometer ZET 7152-N-VER.1 has a compact triaxial sensing element; it is purposed to measure linear acceleration and vibration acceleration variable component in three mutually perpendicular planes. Light weight of sensing element (only 1.5 g) considerably decreases self-mass load effect, and compact dimensions (8.5×8.5×8.5 mm) allow using ZET 7152-N-VER.1 digital accelerometer to measure vibration in small work-area systems.
-
SPECTRO MIDEX -
SPECTRO Analytical Instruments GmbH
The SPECTRO MIDEX is known to be an all-round talent for the fast, non-destructive analysis of small spots and the rapid mapping of large surfaces (up 233x160 mm, 9.2x6.3’’) in research and development as well is in compliance screening applications as many elemental analysis tasks in industry, research and the sciences require a non-destructive measuring system that is extremely sensitive and offers a small measuring spot.
-
ZET 7052-N -
ZETLAB Company
Digital accelerometer ZET 7052-N is equipped with a compact sensing element and is designed for linear acceleration and vibration acceleration variable constituent measurement via three mutually perpendicular planes. Small weight of sensing element (1,5 g) considerably reduces self-mass load and compact dimensions (8,5×8,5×8,5 mm) enable use of the digital accelerometer ZET 7052-N for vibration measurements in systems with small active area.